Our KMI 201T shear fixture consists of a bar of rectangular cross section with two supports on which the sample is placed with the loading member midway between the supports. The fixture incorporates a guided upper anvil to ensure parallel loading of the specimen. This test procedure has a smaller test span and the specimen thickness ratio is adopted to increase the level of shear stress relative to the flexural stress in the test specimen to encourage interlinear shear failure.